NICE encourages further research comparing ultrasound-enhanced, catheter-directed thrombolysis for deep vein thrombosis against catheter-directed thrombolysis alone. Patient selection should be documented, including the duration and extent of thrombosis. The dose of thrombolytic agent used and the duration of thrombolysis should be reported, together with all complications. Outcome measures should include the success of thrombolysis (complete, partial or failed) and long-term sequelae. NICE may update the guidance on publication of further evidence.
- Any explanatory notes
(if applicable) The evidence on ultrasound-enhanced, catheter-directed thrombolysis for deep vein thrombosis raises no major safety concerns over those of catheter-directed thrombolysis (CDT) alone. With regard to efficacy, evidence of any enhancement of thrombolysis over CDT alone is inadequate in quality and quantity. Therefore this procedure should only be used with special arrangements for clinical governance, consent and audit or research.
Source guidance details
- Comes from guidance
- Ultrasound‑enhanced, catheter‑directed thrombolysis for deep vein thrombosis
- Number
- IPG523
- Date issued
- June 2015
Other details
Is this a recommendation for the use of a technology only in the context of research? | No |
Is it a recommendation that suggests collection of data or the establishment of a register? | No |